You need a compact freezer for the lab?
The Eppendorf Innova U535 ULT freezer minimizes operating costs while providing superior protection for your critical samples. A combined insulation based on vacuum insulation panels and polyurethane foam enables extremely low energy consumption. More information

Order Info

Product Information

When it comes to maximizing sample storage capacity, Eppendorf Innova ULT Freezers set the standard. They take advantage of ultra-efficient, ultra-compact vacuum insulation panels which are used in combination with traditional insulation to slim down the freezer wall thickness from 130 mm to 80 mm. These models are ideal for labs short on space.

PhysioCare
Besides sustainability, the main focus of our freezers is on ergonomic aspects. Easy closing of the outer door, ergonomic door handle, display on eye-level, or easy-to-clean stainless steel interior are based on the Eppendorf PhysioCare Concept: Safe grip but very light forces needed to open and close the freezer door.


Cost of ownership
When investing in a new ULT freezer, the product price itself is only one aspect. Others include the long-term costs of power consumption and the costs of service and spare parts. Keep in mind, a high-quality ULT freezer will do its job in the lab for 10 years or more.


Sample safety
The Innova line is equipped with reliable heavy-duty compressors (2-stage cascade cooling system). Quick pull-down times enable fast re-use after cleaning/defrosting of the instrument. The freezers have short recovery times after opening as well as built-in voltage stabilizers to provide extra sample safety.
Their temperature range is from -50 °C to -86 °C.
For even higher sample safety, the Eppendorf Innova upright freezers can be equipped with CO2/LN2 back-up systems and a chart recorder. Temperature monitor systems can be used to monitor the freezers remotely.


Sustainability
Sustainability for ULT freezers is a challenge: Maintaining extremely low temperatures of -86 °C for 24 hours a day, 7 days a week needs energy.
By following the epGreen concept, the Eppendorf freezer R&D team developed intelligent solutions where energy savings are combined with durable long-lasting product quality and ergonomic aspects. This future-oriented instrument class provides consumption levels which are ahead of most competitors within this volume class.

Support the epGreen initiative with your Eppendorf ULT freezer


Eppendorf Ultra-Low Temperature freezers are among the most energy-efficient in the industry, reducing energy consumption by thousands of kilowatt hours over our competition.


Factors influencing the energy consumption
› Thickness of insulation
› Type of insulation
› Type of cooling liquid
› Efficiency of compressors
› Control of compressor
› Pressure in cooling system
› Style of cooling loops (diameter, length, density,..)
› Sealings of outer door
› Sealings of inner doors
› Insulation of inner doors
› Insulation of outer door


Our part for sustainability
› Production moved into new building with state-of-the-art building insulation to save heating energy and power
› Heat output during final individual unit testing discharges building heating system
› Plastic and cardboard compactors introduced + waste rebate system in place
› Local requirements for waste management (collection of electronic waste like circuit boards, recycling via authorized recycling organizations) and internal guide lines
› Usage of green cooling liquids in Eppendorf ULT freezers for 10 years
› Packaging parts have increasing share of recycled origin
› Packaging is more than 99% recyclable (wood, cardboard, PE-foil)
› REACH + RoHS compliant
› ENERGY STAR® partner
› Marketing material is printed on FSC certified paper, wherever possible focus on pdf only
› Shipment by cargo ship to reduce CO2 footprint

Innova® U535

Lost in samples? Stay organized!
Over many years, you collect hundreds and thousands of samples – samples that are the results of years of hard work – samples of high value. When storing these, it is vital to keep them safe and accessible.
Many scientists still use spreadsheets or even paper-based lists to keep track of their storage. While these solutions may work most of the time, they are susceptible to human error, damage, and misplacement.
Keep track of your samples with eLABInventory
eLABInventory is a sample management software.

Start a free 30-day trial!
Visit www.eLABInventory.com

Innova® U535

Struggling with paper-based documentation?
The eLABJournal Electronic Lab Notebook offers an intuitive and flexible solution to document research and track research data like workflow processes where the ULT freezer is involved. Improve efficiency when documenting, organizing, searching, and archiving collected data. With the free eLABJournal add-ons, you can extend the functionality of eLABJournal to a fully integrated Laboratory Information Management System.

Start a free 30-day trial!
Visit www.eLABJournal.com

Innova® U535

Features

  • Vacuum insulation panels allow for increased internal capacity with the same footprint as traditionally foamed freezers
  • Inner doors are gasketed as well as insulated creating 3 separate compartments minimizing cold air loss while you access your samples
  • Easy-to-read, eye level, flush mounted LED control panel and alarm status
  • Each shelf is adjustable in height for additional storage flexibility
  • Special vacuum vent with plunger ergonomically located at waist level to gain immediate access to your freezer
  • Inner doors can be quickly removed without the need for tools for easier and faster defrosting
  • Full stainless steel interior for easy cleaning during maintenance and defrost cycles; powder-coated steel exterior
  • Special low-temperature outer door seals allow gaskets to remain flexible at –86 °C and prevent ice buildup for easy access to samples
  • Password protection of alarm and temperature setpoints to prevent unauthorized setting changes

Applications

  • ULT freezers are suitable for storage and preservation of all types of biological materials/samples:
  • › Bacteria
  • › Cells
  • › Spores
  • › Pollens
  • › Protozoa
  • › Blood components
  • › DNA
  • › Tissue used in research only
  • › Preservation of chemicals or material testing components for a longer period of time
 Innova® U535Innova® U535
Cooling liquidR404A / R508BR404A / R508B
Cooling typeair-cooledair-cooled
Heat output720 W720 W
InsulationVacuum insulation paneling / polyurethane foamVacuum insulation paneling / polyurethane foam
Capacity535 L535 L
Capacity (ft3)18.9 ft³18.9 ft³
No. of internal doors33
No. of compartments33
Max. racks per freezer1212
Noise level56 dBA56 dB
High-Efficiencynono
Power supply115 V, 60 Hz208 – 230 V, 60 Hz
Max. power consumption13,200 W13,200 W
Footprint (WxD)80 x 86.7 cm80 x 86.7 cm
Temperature range-50 °C to -86 °C-50 °C to -86 °C
Pull-down time to -80 °C4 h14 h1
Box capacity per freezer  
53 mm (2 in) tall boxes336336
64 mm (2.5 in) tall boxes288288
76 mm (3 in) tall boxes240240
102 mm (4 in) tall boxes144144
127 mm (5 in) tall boxes144144
DWP per freezer  
10 cm (4 in) tall boxes504504
Box capacity per rack  
53 mm (2 in) tall boxes2828
64 mm (2.5 in) tall boxes2424
76 mm (3 in) tall boxes2020
102 mm (4 in) tall boxes1212
127 mm (5 in) tall boxes1212
DWP4242
1Empty freezer with shelves fitted, upright freezers only, pull down from 21 – 23 °C ambient conditions.
Innova® U535
Video: Innova® U535 – Video – Innova ULT Freezers